Mixer Performance Simulations: Difference between revisions
Jump to navigation
Jump to search
(4 intermediate revisions by the same user not shown) | |||
Line 104: | Line 104: | ||
**Fill in '''Amplitude 1 (Vpk) with the amplitude of your LO signal | **Fill in '''Amplitude 1 (Vpk) with the amplitude of your LO signal | ||
**Click OK | **Click OK | ||
*In the Analog Design Environment, enable the '''pss''' analysis | |||
**Verify that only '''flo''' is displated in the '''Fundamental tones''' section | |||
**Select '''Beat Frequency''' and click '''Auto Calculated''' | |||
**Select '''Number of harmonics''' under '''Output harmonics''' and fill in the value of 0 | |||
**Set the '''Accuracy Defaults (errpreset)''' to '''conservative''' | |||
**Set the '''Additional Time for Stabalizatoin (tstab)''' to a time larger that the settling time of your system | |||
***Run a short '''tran''' simulation to find the time when all of the voltages in your mixer have settled and there is no "ringing" | |||
**Click OK | |||
*In the Analog Design Environment select the pnoise analysis | |||
**The '''PSS Beat Frequency (Hz)''' should read 2.2G (2.6G if you are using high-side injection) | |||
**Set '''Output Frequency Sweep Range (Hz)''' to '''Start-Stop''' | |||
**Set '''Start''' to '''1 MHz''' and '''Stop''' to '''1 GHz''' | |||
**Set '''Sweep Type''' to '''Logarithmic''' | |||
**Use 100 points per decade | |||
**Under '''sidebands''' select '''Maximum sideband''' and set it to 30 | |||
**Under '''Output''', select '''voltage''' and select the appropriate node for the IF on your schematic | |||
**For the '''Input Source''' select '''port''' and select the RF port | |||
**For '''Reference side-band''' select '''Enter in field''' and enter -1 | |||
**Click OK | |||
*Run the Simulation | |||
*To view the results for the conversion gain simulatoin click <code>Results -> Direct Plot -> Main Form ...</code> | |||
**Set the '''Analysis''' to '''pnoise''' | |||
**Set the '''Function''' to '''Noise Figure''' | |||
**Click '''Plot''' | |||
==Linearity using IIP3== | ==Linearity using IIP3== | ||
*You must first instance ports for the RF, LO, and IF ports of the mixer (<code>analogLib -> Sources -> Independent -> port</code>). If your mixer requires differential inputs/outputs then refer to the separate tutorial on how to drive differential signals. | |||
*Edit the properties of the RF port | |||
**Set the '''Resistance''' to 50 Ω and the '''Port number''' to 1 | |||
**Set the '''Source type''' to '''sine''' | |||
**Enter '''frf''' for the '''Frequency name 1''' | |||
**Enter 2.4 GHz for '''Frequency 1''' | |||
**Enter '''prf''' for Amplitude 1 (dBm)''' | |||
**Click on '''Display small signal params''' and enter '''prf''' in the '''PAC magnitude (dBm)''' field | |||
**Click OK | |||
*Edit the properties of the LO port | |||
**Set the '''Resistance''' to 50 Ω | |||
**Set the '''Port number''' to 2 | |||
**Set the '''Source type''' to '''sine''' | |||
**Fill in the '''flo''' for the '''Frequency name 1''' | |||
**'''Frequency 1''' should be either 2.2 GHz (for low-side injection) or 2.6 GHz (for high-side injection) | |||
***This is the frequency of the local oscillator signal | |||
**Fill in '''Amplitude 1 (Vpk) with the amplitude of your LO signal | |||
**Click OK | |||
*Edit the IF port | |||
**Set the '''Resistance''' to 50 Ω and the '''Port number''' to 3 | |||
**Set the '''Source type''' to '''dc''' | |||
**Click OK | |||
*In the Analog Design Environment, enable the '''pss''' analysis | |||
**Verify that both '''frf''' and '''flo''' are displated in the '''Fundamental tones''' section | |||
**Select '''Beat Frequency''' and click '''Auto Calculated''' | |||
**Select '''Number of harmonics''' under '''Output harmonics''' and fill in the value of 2 | |||
**Set the '''Accuracy Defaults (errpreset)''' to '''conservative''' | |||
**Select '''Sweep''' and make sure that '''Variable''' is selected and enter '''prf''' for '''Variable Name''' | |||
**Under '''Sweep Range''' select '''Start-Stop''' | |||
**Set '''Start''' to -25 and '''Stop''' to +5 | |||
**Set '''Sweep Type''' to '''Linear''' | |||
**Set '''Step Size''' to 5 | |||
**Click OK | |||
*In the Analog Design Environment enable the '''pac''' analysis | |||
**Under '''Input Frequency Sweep Range (Hz)''' chosse '''Single-Point''' | |||
**Set '''Freq''' to 2.402 GHz | |||
**Under '''Sidebands''' select '''Array of indicies''' | |||
**Enter -11 -13 (with a space between) in the '''Additional indicies''' field | |||
***These numbers correspond to the harmonic of the beat frequency that corresponds to the fundamental and IM3 components | |||
**Clic OK | |||
*Run the Simulation | |||
*To view the simulation results | |||
**Click <code>Results -> Direct Plot -> Main Form ...</code> | |||
**Under '''Analysis''' select '''pac''' | |||
**Under '''Function''' select '''IPN Curves''' | |||
**For '''Circuit Input Power''' select '''Variable Sweep ("prf")''' | |||
**Enter -20 for '''Input Power Extrapolation Point (dBm)''' | |||
**Under '''1st Order Harmonic''' select '''-11 202M''' | |||
***This is our downconverted fundamental component assuming low-side injection (2.402 GHz - 2.2 GHz = 202 MHz) | |||
**Under '''3rd Order Harmonic''' select -13 198M | |||
***This is our downconverted IM3 component assuming low-side injection ([2*2.4 GHz - 2.402 GHz] - 2.2 GHz = 198 MHz) | |||
**Select the IF port on your schematic |
Latest revision as of 14:27, 7 April 2011
Conversion Gain
- You must first instance ports for the RF, LO, and IF ports of the mixer (
analogLib -> Sources -> Independent -> port
). If your mixer requires differential inputs/outputs then refer to the separate tutorial on how to drive differential signals. - Edit the properties of the RF port
- Set the Resistance to 50 Ω and the Port number to 1
- Set the Source type to dc
- Click OK
- Edit the properties of the LO port
- Set the Resistance to 50 Ω
- Set the Port number to 2
- Set the Source type to sine
- Fill in the flo for the Frequency name 1
- Frequency 1 should be either 2.2 GHz (for low-side injection) or 2.6 GHz (for high-side injection)
- This is the frequency of the local oscillator signal
- Fill in Amplitude 1 (Vpk) with the amplitude of your LO signal
- Click OK
- Edit the IF port
- Set the Resistance to 50 Ω and the Port number to 3
- Set the Source type to dc
- Click OK
- In the Analog Design Environment, enable the pss analysis
- Verify that only flo is displated in the Fundamental tones section
- Select Beat Frequency and click Auto Calculated
- Select Number of harmonics under Output harmonics and fill in the value of 0
- This number of ourput harmonics is required by the pxf analysis that we will use to perform the conversion gain simulation
- Set the Accuracy Defaults (errpreset) to conservative
- Set the Additional Time for Stabalizatoin (tstab) to a time larger that the settling time of your system
- Run a short tran simulation to find the time when all of the voltages in your mixer have settled and there is no "ringing"
- Click OK
- In the Analog Design Environment, select pxf analysis (pxf stands for periodic transfer function)
- Set Sweep type to default
- Under Output Frequency Sweep Range (Hz) select Start-Stop
- Set Start to 1 MHz and Stop to 400 MHz
- Set the Sweep Type to Linear
- Select Number of Steps and set the value to 1000
- Set Sidebands to Maximum Sideband and enter the value 3
- Under Output select probe and then selct the IF port
- Click OK
- Run the simulation
- To view the results for the conversion gain simulatoin click
Results -> Direct Plot -> Main Form ...
- Set the Analysis to pxf
- Set the Function to Voltage Gain
- Set Sweep to sideband
- Select sidebands -1 and 1 (hold down the ctrl key to select multiple sidebands)
- This is the sideband that provides us the conversion gain of our RF frequency of interest
- Set Modifier to dB20
- Click on the RF port in the schematic
LO Feed Through
- You must first instance ports for the RF, LO, and IF ports of the mixer (
analogLib -> Sources -> Independent -> port
). If your mixer requires differential inputs/outputs then refer to the separate tutorial on how to drive differential signals. - Edit the properties of the RF port
- Set the Resistance to 50 Ω and the Port number to 1
- Set the Source type to sine
- Enter frf for the Frequency name 1
- Enter 2.4 GHz for Frequency 1
- Enter prf for Amplitude 1 (dBm)
- Click OK
- Edit the properties of the LO port
- Set the Resistance to 50 Ω
- Set the Port number to 2
- Set the Source type to sine
- Fill in the flo for the Frequency name 1
- Frequency 1 should be either 2.2 GHz (for low-side injection) or 2.6 GHz (for high-side injection)
- This is the frequency of the local oscillator signal
- Fill in Amplitude 1 (Vpk) with the amplitude of your LO signal
- Click OK
- Edit the IF port
- Set the Resistance to 50 Ω and the Port number to 3
- Set the Source type to dc
- Click OK
- In the Analog Design Environment, enable the pss analysis
- Verify that both frf and flo are displated in the Fundamental tones section
- Select Beat Frequency and click Auto Calculated
- The beat frequency should be 200 MHz (your IF frequency)
- Select Number of harmonics under Output harmonics and fill in the value of 15
- Set the Accuracy Defaults (errpreset) to conservative
- Set the Additional Time for Stabalizatoin (tstab) to a time larger that the settling time of your system
- Run a short tran simulation to find the time when all of the voltages in your mixer have settled and there is no "ringing"
- Click OK
- Run the simulatoin
- To view the results for the conversion gain simulatoin click
Results -> Direct Plot -> Main Form ...
- Set the Analysis to pss
- Set the Function to Voltage
- Choose Differential Nets under the Select optoin if you have a differential output
- Set Sweep to spectrum
- Set Signal Level to Peak
- Choose dB20 for the Modifier
- Select the IF output nets on the schematic to plot the result
- Place a marker on the harmonic that appears at you LO frequency (2.2 GHz for low-side injection or 2.6 GHz for high-side injection)and read the value
Noise Figure
- You must first instance ports for the RF, LO, and IF ports of the mixer (
analogLib -> Sources -> Independent -> port
). If your mixer requires differential inputs/outputs then refer to the separate tutorial on how to drive differential signals. - This simulation does not require an IF port so remove the IF port (and accompanying balun circuitry if you have a differential IF signal)
- Edit the properties of the RF port
- Set the Resistance to 50 Ω and the Port number to 1
- Set the Source type to dc
- Click OK
- Edit the properties of the LO port
- Set the Resistance to 50 Ω
- Set the Port number to 2
- Set the Source type to sine
- Fill in the flo for the Frequency name 1
- Frequency 1 should be either 2.2 GHz (for low-side injection) or 2.6 GHz (for high-side injection)
- This is the frequency of the local oscillator signal
- Fill in Amplitude 1 (Vpk) with the amplitude of your LO signal
- Click OK
- In the Analog Design Environment, enable the pss analysis
- Verify that only flo is displated in the Fundamental tones section
- Select Beat Frequency and click Auto Calculated
- Select Number of harmonics under Output harmonics and fill in the value of 0
- Set the Accuracy Defaults (errpreset) to conservative
- Set the Additional Time for Stabalizatoin (tstab) to a time larger that the settling time of your system
- Run a short tran simulation to find the time when all of the voltages in your mixer have settled and there is no "ringing"
- Click OK
- In the Analog Design Environment select the pnoise analysis
- The PSS Beat Frequency (Hz) should read 2.2G (2.6G if you are using high-side injection)
- Set Output Frequency Sweep Range (Hz) to Start-Stop
- Set Start to 1 MHz and Stop to 1 GHz
- Set Sweep Type to Logarithmic
- Use 100 points per decade
- Under sidebands select Maximum sideband and set it to 30
- Under Output, select voltage and select the appropriate node for the IF on your schematic
- For the Input Source select port and select the RF port
- For Reference side-band select Enter in field and enter -1
- Click OK
- Run the Simulation
- To view the results for the conversion gain simulatoin click
Results -> Direct Plot -> Main Form ...
- Set the Analysis to pnoise
- Set the Function to Noise Figure
- Click Plot
Linearity using IIP3
- You must first instance ports for the RF, LO, and IF ports of the mixer (
analogLib -> Sources -> Independent -> port
). If your mixer requires differential inputs/outputs then refer to the separate tutorial on how to drive differential signals. - Edit the properties of the RF port
- Set the Resistance to 50 Ω and the Port number to 1
- Set the Source type to sine
- Enter frf for the Frequency name 1
- Enter 2.4 GHz for Frequency 1
- Enter prf for Amplitude 1 (dBm)
- Click on Display small signal params and enter prf in the PAC magnitude (dBm) field
- Click OK
- Edit the properties of the LO port
- Set the Resistance to 50 Ω
- Set the Port number to 2
- Set the Source type to sine
- Fill in the flo for the Frequency name 1
- Frequency 1 should be either 2.2 GHz (for low-side injection) or 2.6 GHz (for high-side injection)
- This is the frequency of the local oscillator signal
- Fill in Amplitude 1 (Vpk) with the amplitude of your LO signal
- Click OK
- Edit the IF port
- Set the Resistance to 50 Ω and the Port number to 3
- Set the Source type to dc
- Click OK
- In the Analog Design Environment, enable the pss analysis
- Verify that both frf and flo are displated in the Fundamental tones section
- Select Beat Frequency and click Auto Calculated
- Select Number of harmonics under Output harmonics and fill in the value of 2
- Set the Accuracy Defaults (errpreset) to conservative
- Select Sweep and make sure that Variable is selected and enter prf for Variable Name
- Under Sweep Range select Start-Stop
- Set Start to -25 and Stop to +5
- Set Sweep Type to Linear
- Set Step Size to 5
- Click OK
- In the Analog Design Environment enable the pac analysis
- Under Input Frequency Sweep Range (Hz) chosse Single-Point
- Set Freq to 2.402 GHz
- Under Sidebands select Array of indicies
- Enter -11 -13 (with a space between) in the Additional indicies field
- These numbers correspond to the harmonic of the beat frequency that corresponds to the fundamental and IM3 components
- Clic OK
- Run the Simulation
- To view the simulation results
- Click
Results -> Direct Plot -> Main Form ...
- Under Analysis select pac
- Under Function select IPN Curves
- For Circuit Input Power select Variable Sweep ("prf")
- Enter -20 for Input Power Extrapolation Point (dBm)
- Under 1st Order Harmonic select -11 202M
- This is our downconverted fundamental component assuming low-side injection (2.402 GHz - 2.2 GHz = 202 MHz)
- Under 3rd Order Harmonic select -13 198M
- This is our downconverted IM3 component assuming low-side injection ([2*2.4 GHz - 2.402 GHz] - 2.2 GHz = 198 MHz)
- Select the IF port on your schematic
- Click